Lucent Omni Stack LS 6224: различия между версиями
Sirmax (обсуждение | вклад) |
Sirmax (обсуждение | вклад) |
||
Строка 504: | Строка 504: | ||
console(config)# |
console(config)# |
||
console# |
console# |
||
+ | </PRE> |
||
+ | |||
+ | Добавляю все вланы во все гигабитные порты. <PRE> |
||
+ | Порты - trunk. |
||
+ | <PRE> |
||
+ | console# configure |
||
+ | console(config)#interface range ethernet g1,g2,g3,g4 |
||
+ | console(config-if)# switchport mode trunk |
||
+ | console(config-if)# switchport trunk allowed vlan |
||
+ | console(config-if)# switchport trunk allowed vlan add 201-224 |
||
+ | 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 201 |
||
+ | 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 202 |
||
+ | 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 203 |
||
+ | 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 204 |
||
+ | 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 205 |
||
+ | 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 206 |
||
+ | 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 207 |
||
+ | 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 208 |
||
+ | 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 209 |
||
+ | 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 210 |
||
+ | 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 211 |
||
+ | 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 212 |
||
+ | 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 213 |
||
+ | 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 214 |
||
+ | 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 215 |
||
+ | 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 216 |
||
+ | 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 217 |
||
+ | 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 218 |
||
+ | 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 219 |
||
+ | 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 220 |
||
+ | 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 221 |
||
+ | 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 222 |
||
+ | 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 223 |
||
+ | 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 224 |
||
</PRE> |
</PRE> |
||
Версия 09:39, 15 июня 2009
Lucent Omni Stack LS 6224
В руки попал коммутатор Lucent Omni Stack LS 6224. Задача - всесторонне протестировать.
При цене $296 прямой конкурент DES-3526
Сравнительная характеристика
В таблице указаны фичи и
Authentication |
Console, Telnet, web – User name / password, RADIUS, TACACS+ Web – HTTPS; Telnet – SSH SNMP v1/2c - Community strings SNMP version 3 – MD5 or SHA password Port – IEEE 802.1x |
Все вцелом аналогично Длинку. Из плюсов - ssh работает с приемлемой скоростью. |
Access Control Lists |
Supports up to 1K IP or MAC ACLs |
Пока сложно сказать, но Content-Filter у Длинка достаточно гибкие, хотя их и не много. TODO: Cравнить подробнее. |
DHCP Client |
Supported |
Фича сомнительной необходимости, есть у всех. |
DNS Server |
Supported |
Назначение неясно. TODO:Уточнить |
Port Configuration |
Speed, duplex mode and flow control |
У всех коммутатров абсолютно одинаково. |
Rate Limiting |
Input and output rate limiting per port |
с каким шагом? TODO: уточнить |
Port Mirroring |
One or more ports mirrored to single analysis port |
Стандартная фича. TODO: Проверить работу. |
Port Trunking |
Supports up to 8 trunks using either static or dynamic trunking (LACP) |
Стандартная фича. |
Broadcast Storm Control |
Supported |
TODO: Проверить работу. |
Static Address |
Up to 16K MAC addresses in the forwarding table |
Уточнить что имелось ввиду. статик мак в современной провайдерской сети скорее вреден. Если размер таблицы коммутации 16к - то это хороший результат. |
IEEE 802.1D Bridge |
Supports dynamic data switching and addresses learning |
|
Store-and-Forward Switching |
Supported to ensure wire-speed switching while eliminating bad frames |
|
Spanning Tree Protocol |
Supports standard STP, Rapid Spanning Tree Protocol (RSTP), Multiple Spanning Trees (MSTP). |
Насколько стабильна работа? |
Virtual LANs |
Up to 255 using IEEE 802.1Q, port-based, protocol-based, or private VLANs GVRP |
255 Вланов вполне достаточно для коммутатора доступа. |
Traffic Prioritization |
Default port priority, traffic class map, queue scheduling, IP Precedence, or Differentiated Services Code Point (DSCP) and TCP/UDP Port |
Проверить работу, хотя фактически на данный момент мне не нужна приоритезация траффика. |
STP Root Guard |
Prevents devices outside the network core from being assigned the spanning tree root. |
|
STP BPDU Guard |
Used as a security mechanism to protect the network from invalid configurations. |
|
802.1x - MAC Authentication |
MAC authentication ensures that end-user stations meet security policies criteria, and protects networks from viruses. |
Не использую. |
DHCP Snooping |
Expands network security by providing a firewall security between untrusted interfaces and DHCP servers. |
Совершенно необходимая фича. Проверить работу. |
DHCP Option 82 |
Enables to add information for the DHCP server on request. |
Совершенно необходимая фича. |
IP Source Address Guard |
Restricts IP traffic on non-routed, Layer 2 interfaces by filtering traffic. This feature is based on the DHCP snooping binding database and on manually configured IP source bindings. |
Совершенно необходимая фича. |
ARP Inspection |
Classic Address Resolution Protocol is a TCP/IP protocol that translates IP addresses into MAC addresses. |
Загрузка
Подключенеи через консольный кабель, 9600 8N1
RJ45- 1. бело-оранжевый 2. оранжевый 3. бело-зелёный 4. синий 5. бело-синий 6. зелёный 7. бело-коричневый 8. коричневый. DB9 1. пусто... 2. зеленый 3. бело-зеленый 4. оранжевый 5. синий,бело-синий 6. бело-коричневый 7. бело-оранжевый 8. коричневый 9. пусто...
Кабель зеркальный относительно Cisco, и предположительно может быть собран из roll-over кабеля.
Welcome to minicom 2.3 OPTIONS: I18n Compiled on Jan 1 2009, 02:50:29. Port /dev/ttyUSB0 Press CTRL-A Z for help on special keys Boot1 Checksum Test...............................PASS Boot2 Checksum Test...............................PASS Flash Image Validation Test.......................PASS BOOT Software Version 1.0.0.12 Built 19-Oct-2006 09:07:37 OS6200 board, based on PPC8247 128 MByte SDRAM. I-Cache 16 KB. D-Cache 16 KB. Cache Enabled. Autoboot in 2 seconds - press RETURN or Esc. to abort and enter prom. Preparing to decompress... 100% Decompressing SW from image-2 100% OK Running from RAM... ********************************************************************* *** Running SW Ver. 1.5.0.93 Date 15-Jun-2007 Time 12:08:50 *** ********************************************************************* HW version is 00.00.01 Base Mac address is: 00:12:хх:хх:хх:хх Dram size is : 128M bytes Dram first block size is : 98304K bytes Dram first PTR is : 0x2000000 Flash size is: 16M 01-Jan-2000 01:01:04 %CDB-I-LOADCONFIG: Loading running configuration. 01-Jan-2000 01:01:04 %CDB-I-LOADCONFIG: Loading startup configuration. Device configuration: CPLD revision: 1.03 PCB revision: R-0A Slot 1 - OmniStack LS 6224 HW Rev. 1.3 ------------------------------------ -- Unit Standalone -- ------------------------------------ Tapi Version: v1.3.3.1 Core Version: v1.3.3.1 01-Jan-2000 01:01:19 %INIT-I-InitCompleted: Initialization task is completed 01-Jan-2000 01:01:19 %SNMP-I-CDBITEMSNUM: Number of running configuration items loaded: 2 01-Jan-2000 01:01:19 %SNMP-I-CDBITEMSNUM: Number of startup configuration items loaded: 2 01-Jan-2000 01:01:20 %Box-I-SFP-PRESENT-CHNG: unit_id 1 SFP 0 status is not present. 01-Jan-2000 01:01:20 %Box-I-SFP-PRESENT-CHNG: unit_id 1 SFP 1 status is not present. console> 01-Jan-2000 01:01:22 %LINK-W-Down: e1 01-Jan-2000 01:01:22 %LINK-W-Down: e2 01-Jan-2000 01:01:22 %LINK-W-Down: e3 01-Jan-2000 01:01:22 %LINK-W-Down: e4 01-Jan-2000 01:01:22 %LINK-W-Down: e5 01-Jan-2000 01:01:22 %LINK-W-Down: e6 01-Jan-2000 01:01:22 %LINK-W-Down: e7 01-Jan-2000 01:01:22 %LINK-W-Down: e8 01-Jan-2000 01:01:22 %LINK-W-Down: e9 01-Jan-2000 01:01:23 %LINK-W-Down: e10 01-Jan-2000 01:01:23 %LINK-W-Down: e11 01-Jan-2000 01:01:23 %LINK-W-Down: e12 01-Jan-2000 01:01:23 %LINK-W-Down: e13 01-Jan-2000 01:01:23 %LINK-W-Down: e14 01-Jan-2000 01:01:23 %LINK-W-Down: e15 01-Jan-2000 01:01:23 %LINK-W-Down: e16 01-Jan-2000 01:01:23 %LINK-W-Down: e17 01-Jan-2000 01:01:23 %LINK-W-Down: e18 01-Jan-2000 01:01:23 %LINK-W-Down: e19 01-Jan-2000 01:01:23 %LINK-W-Down: e20 01-Jan-2000 01:01:23 %LINK-W-Down: e21 01-Jan-2000 01:01:23 %LINK-W-Down: e22 01-Jan-2000 01:01:23 %LINK-W-Down: e23 01-Jan-2000 01:01:23 %LINK-W-Down: e24 01-Jan-2000 01:01:23 %LINK-W-Down: g1 01-Jan-2000 01:01:23 %LINK-W-Down: g2 01-Jan-2000 01:01:23 %LINK-W-Down: g3 01-Jan-2000 01:01:23 %LINK-W-Down: g4 01-Jan-2000 01:01:24 %Box-I-FAN-STAT-CHNG: FAN# 1 status is - operational. 01-Jan-2000 01:01:24 %Entity-I-SEND-ENT-CONF-CHANGE-TRAP: entity configuration change trap. 01-Jan-2000 01:01:24 %Box-I-PS-STAT-CHNG: PS# 1 status is - operational. 01-Jan-2000 01:01:26 %LINK-I-Up: Vlan 1 01-Jan-2000 01:01:26 %LINK-I-Up: g3 01-Jan-2000 01:01:56 %STP-W-PORTSTATUS: g3: STP status Forwarding 01-Jan-2000 01:03:30 %INIT-I-Startup: Cold Startup console>
Предварительное изучение интерфейса CLI
Первое впечателение -CISCO-Like. Хотя, вцелом, менее удобно. (с непривычки). Запись коонфига
copy running-config startup-config Overwrite file [startup-config] ?[Yes/press any key for no].... 01-Jan-2000 01:49:55 %COPY-I-FILECPY: Files Copy - source URL running-config destination URL flash://startup-config 01-Jan-2000 01:49:58 %COPY-W-TRAP: The copy operation was completed successfully
Посмотреть конфиг
sh run
Итнерфейс управления (в 1-м VLAN)
interface vlan 1 ip address 172.16.37.205 255.255.255.0 exit
Нагрузка
На коммутаторе с пустым конфигом и одним линком (25 порт)
show system tcam utilization TCAM utilization: 13%
# show cpu utilization CPU utilization service is on. CPU utilization --------------- five seconds:5% ;one minute:5% ;five minutes:6%
Настройка VLAN
В моем случае попробую схемы Vlna-per-Customer, соответвенно у меня каждый из 24 портов в своем влане, магистральные порты - во всех вланах. Управление для простоты в 1-м ВЛАН.
Создаю VLANs 201-224
#configure vlan database console(config-vlan)# vlan 201 ... console(config-vlan)# vlan 224 exit
Добавляю порты 1-24 каждый в свой VLAN, режим access (untag в терминах DLink)
В примере порт 2 (e2, в терминах Cisco это был бы Fa0/2). Для остальных - аналогично.
Отмечу немного непривычное именование портов, FastEthernet = e1 - e2, GigabitEthernet = g1 - g3
console# conf# console(config)# interface ethernet e2 console(config-if)# switchport mode access console(config-if)# switchport access vlan 202 console(config-if)# description "---=== Access-Port=2 ===---" console(config-if)# ex console(config)# console#
Добавляю все вланы во все гигабитные порты.
Порты - trunk. <PRE> console# configure console(config)#interface range ethernet g1,g2,g3,g4 console(config-if)# switchport mode trunk console(config-if)# switchport trunk allowed vlan console(config-if)# switchport trunk allowed vlan add 201-224 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 201 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 202 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 203 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 204 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 205 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 206 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 207 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 208 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 209 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 210 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 211 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 212 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 213 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 214 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 215 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 216 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 217 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 218 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 219 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 220 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 221 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 222 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 223 01-Jan-2000 17:22:09 %LINK-I-Up: Vlan 224
Настройка SNMP
Вцелом, аналогично всем другим коммутаторам с которыми мне приходилось работать.
Создать view:
snmp-server view ALL 1 included
Задать коммюнити и view. Опционально - IP адресс.
snmp-server community public ro view ALL
show snmp Community-String Community-Access View name IP address -------------------- ------------------ -------------- ------------ public read only ALL All
Проверить работу: (вывод поскипан).