<PRE>
  +
DES3526:user#cable_diag ports 1-24
  +
Command: cable_diag ports 1-24
  +
  +
Perform Cable Diagnostics ...
  +
  +
Port Type Link Status Test Result Cable Length (M)
  +
---- ------ ------------- ----------------------------- ----------------
  +
1 FE Link Down OK -
  +
2 FE Link Down No Cable -
  +
3 FE Link Down No Cable -
  +
4 FE Link Down No Cable -
  +
5 FE Link Down No Cable -
  +
6 FE Link Down No Cable -
  +
7 FE Link Down No Cable -
  +
8 FE Link Down No Cable -
  +
9 FE Link Down No Cable -
  +
10 FE Link Down Pair1 Open at 22 M -
  +
Pair2 Open at 22 M
  +
11 FE Link Down Pair1 Open at 25 M -
  +
Pair2 Open at 25 M
  +
12 FE Link Down Pair1 Open at 88 M -
  +
Pair2 Open at 88 M
  +
13 FE Link Down OK -
  +
14 FE Link Up OK 40
  +
15 FE Link Down Pair1 Open at 18 M -
  +
Pair2 Open at 18 M
  +
16 FE Link Up OK 69
  +
17 FE Link Down Pair1 Open at 34 M -
  +
Pair2 Open at 33 M
  +
18 FE Link Down Pair1 Open at 4 M -
  +
Pair2 Open at 4 M
  +
19 FE Link Up OK 34
  +
20 FE Link Down OK -
  +
21 FE Link Up OK 40
  +
22 FE Link Down Pair1 Open at 29 M -
  +
Pair2 Open at 29 M
  +
23 FE Link Down No Cable -
  +
24 FE Link Down Pair1 Open at 22 M -
  +
Pair2 Open at 22 M
  +
</PRE>
  +
  +
Возможные значения:
  +
<BR>
  +
Pair Open - обрыв на растоянии ХХ метров.<BR>
  +
Link Up, длинна ХХ метров.<BR>
  +
Link Down, OK - нельзя измерить длинну кабеля (но нагрузка есть)<BR>
  +
Link Down, No Cable - нет кабеля.<BR>
  +
 
==Использование с SNMP==
 
==Использование с SNMP==

Версия 15:29, 23 июня 2009

Кабельный тестер

В коммутаторы DES-3526 и DES-3550 (возможно DES-3028 и DES-3052) встроен кабельный тестер который позволяет определять (довольно приблезительно) длинну кабеля.

Использование с консоли

Комманда не требует админских привелений:

DES3526:user#cable_diag ports 1-24
Command: cable_diag ports 1-24

 Perform Cable Diagnostics ...

 Port   Type    Link Status            Test Result           Cable Length (M)
 ----  ------  -------------  -----------------------------  ----------------
  1     FE      Link Down      OK                             -
  2     FE      Link Down      No Cable                       -
  3     FE      Link Down      No Cable                       -
  4     FE      Link Down      No Cable                       -
  5     FE      Link Down      No Cable                       -
  6     FE      Link Down      No Cable                       -
  7     FE      Link Down      No Cable                       -
  8     FE      Link Down      No Cable                       -
  9     FE      Link Down      No Cable                       -
  10    FE      Link Down      Pair1 Open      at 22  M       -
                               Pair2 Open      at 22  M
  11    FE      Link Down      Pair1 Open      at 25  M       -
                               Pair2 Open      at 25  M
  12    FE      Link Down      Pair1 Open      at 88  M       -
                               Pair2 Open      at 88  M
  13    FE      Link Down      OK                             -
  14    FE      Link Up        OK                             40
  15    FE      Link Down      Pair1 Open      at 18  M       -
                               Pair2 Open      at 18  M
  16    FE      Link Up        OK                             69
  17    FE      Link Down      Pair1 Open      at 34  M       -
                               Pair2 Open      at 33  M
  18    FE      Link Down      Pair1 Open      at 4   M       -
                               Pair2 Open      at 4   M
  19    FE      Link Up        OK                             34
  20    FE      Link Down      OK                             -
  21    FE      Link Up        OK                             40
  22    FE      Link Down      Pair1 Open      at 29  M       -
                               Pair2 Open      at 29  M
  23    FE      Link Down      No Cable                       -
  24    FE      Link Down      Pair1 Open      at 22  M       -
                               Pair2 Open      at 22  M

Возможные значения:
Pair Open - обрыв на растоянии ХХ метров.
Link Up, длинна ХХ метров.
Link Down, OK - нельзя измерить длинну кабеля (но нагрузка есть)
Link Down, No Cable - нет кабеля.

Использование с SNMP