SuperMicro X9SCL

Материал из noname.com.ua
Перейти к навигацииПерейти к поиску

X9SCL

X9SCL+-F rev 1.0

Проблема АB

Если при попытке зайти в биос пишет на синем AB - надо сбросить дату (загрущившись в ОС или сбросив настройки Bios) ()

Инструкция

Media:MNL-1270.pdf

11

./bootutil64e  -?

RUNNING BootUtil
================
The syntax for issuing BootUtil command-line options is:

BOOTUTIL -[OPTION] or -<OPTION>=<VALUE>


COMMAND LINE OPTIONS
====================
BootUtil accepts one executable option and its associated non-executable
options in an execution. If conflicting executable options are specified,
BootUtil exits with an error.

The options, where applicable, are listed in logical groups.

NOTE: If you run BootUtil without any command-line options, the utility
displays a list of all supported Intel network ports found in the system.


GENERAL OPTIONS:
-? or -HELP
Displays a list of command-line options.

> Press ENTER key to continue, 'q' to exit:

-ALL
Selects all supported network ports found in the system.

-64d
Disables 64-bit BAR (Base Address Register) addressing on the selected port.
This restricts the system BIOS to assigning 32-bit BARs to the port.

-64e
Enables 64-bit BAR addressing on the selected port.

-BLINK
Blinks the LED on the selected port for ten seconds.

-DEVID=[Device ID]
Selects the network port specified by [Device ID]. [Device ID] is a 4 digit
hexadecimal number, prepended by 0x.

-EXITCODES
Displays exit codes returned to the OS environment by BootUtil.

-E
Enumerates all supported network ports in the system.


> Press ENTER key to continue, 'q' to exit:

-FILE=[FILENAME]
Specifies the file name for -SAVEIMAGE, -RESTOREIMAGE, -SAVECONFIG,
-RESTORECONFIG, -UP or -UPDATE options.

-IMAGEVERSION or -IV
Displays the firmware image type and version number from the specified source.
If no source is specified, displays the image type and version number from the
local BootIMG.FLB file. Use -FILE to specify a different file. Use -NIC to
specify a port. Use -ALL to display the firmware image types and version
numbers of images loaded onto all ports in the system. If a port does not have
an image loaded, or is not an Intel Ethernet port, the port will not be
included in the -ALL output.

-MACADDR=[MAC address string]
Selects the network port specified by [MAC address string]. [MAC address
string] is a 12 digit number. Separators (":" or "-") are allowed but not
required.

-NIC=XX
Selects a specific network port in the system.

-NODPL
With command, BootUtil does not display the PCI device location.

> Press ENTER key to continue, 'q' to exit:


-O=[FILENAME]
Must be used with -E . Saves a list of all NICs and their MAC addresses to the
specified file.

-P
With this command, BootUtil pauses screen after displaying every 25th line. In
pause mode, last line of the screen will contain information that:
  - screen has been paused, and
  - user can press Enter to continue


POWER MANAGEMENT OPTIONS:

-WOLENABLE or -WOLE
Enables Wake On LAN (WOL) functionality on the selected port.

-WOLDISABLE or -WOLD
Disables Wake On LAN (WOL) functionality on the selected port.


ADAPTER FLASH ENABLE/DISABLE OPTIONS:


> Press ENTER key to continue, 'q' to exit:

-BOOTENABLE=[PXE or DISABLED]
Selects flash firmware type to enable or disable on the selected port. The
combo option ROM could have all capabilities. This command will NOT WORK on
monolithic Option ROMs.

NOTE: This manual command is not applicable to the UEFI network driver. The
UEFI network driver is enabled by default and loaded automatically unless
network ports are already used by other flash firmware.

  BOOTENABLE=DISABLED
  Disables PXE functionalities for legacy BIOS.

-FLASHENABLE or -FE
Enables the capability to run flash firmware on the selected adapter.

NOTE: This parameter is not supported on the following adapters:
  - Intel(R) Gigabit ET Quad Port Mezzanine Card
  - Intel(R) Ethernet X520 10GbE Dual Port KX4 Mezz
  - Intel(R) Ethernet X520 10GbE Dual Port KX4-KR Mezz

-FLASHDISABLE or -FD
Disables the capability to run flash firmware on the selected adapter.


> Press ENTER key to continue, 'q' to exit:

NOTE: This parameter is not supported on the following adapters:
  - Intel(R) Gigabit ET Quad Port Mezzanine Card
  - Intel(R) Ethernet X520 10GbE Dual Port KX4 Mezz
  - Intel(R) Ethernet X520 10GbE Dual Port KX4-KR Mezz


FLASH PROGRAMMING OPTIONS:

-QUIET
Runs BootUtil without confirmation prompts. This option is used with
-IMAGEVERSION, -UP, -UPDATE, -RESTOREIMAGE, or -HELP option.

-RESTOREIMAGE or RI
Restores a previously-saved firmware image to the same network adapter using
the -NIC option. The source file is specified by the -FILE option.

-SAVEIMAGE or SI
Saves the existing firmware image in the flash memory of the adapter specified
by the -NIC option to a disk file. The destination file is specified by the
-FILE option.

-UP or -UPDATE=[ROMType] [-FILE=Filename]
Updates the flash memory of the adapter specified by the -NIC option with the

> Press ENTER key to continue, 'q' to exit:

given FLB flash firmware image file. If -QUIET is not specified, the user is
prompted to confirm overwriting the existing firmware image before upgrading.
If a Filename is not provided, the utility looks for the default <bootimg.FLB>
file which contains all image types.

The following examples use PXE, but could also be efi or efi64.
  Bootutil -Nic=x -up=pxe
  Bootutil -Nic=x -up=pxe -file=pxeimg.flb

If your adapter supports a combo option rom, the following command option
automatically detects the supported combo image and programs the adapter with
that image.
  -up=combo
    up=pxe+efi is valid.


PXE BOOT CONFIGURATION OPTIONS: (Can be used with -NIC or -ALL)

-DEFAULTCONFIG or -DEFCFG
Sets the PXE configuration of the selected NIC back to default settings.

-MODE
This parameter should not be used except as advised by Intel Support personnel.

> Press ENTER key to continue, 'q' to exit:


-TITLEENABLE OR -TLE
Enables Initial Title Message.

-TITLEDISABLE OR -TLD
Disables Initial Title Message.

1

ethtool -i  eno2
driver: e1000e
version: 5.15.0-94-generic
firmware-version: 2.1-2
expansion-rom-version:
bus-info: 0000:03:00.0
supports-statistics: yes
supports-test: yes
supports-eeprom-access: yes
supports-register-dump: yes
supports-priv-flags: yes
ubuntu@storage-00:~$ sudo su -
[sudo] password for ubuntu:
root@storage-00:~# lspci
00:00.0 Host bridge: Intel Corporation Xeon E3-1200 Processor Family DRAM Controller (rev 09)
00:1a.0 USB controller: Intel Corporation 6 Series/C200 Series Chipset Family USB Enhanced Host Controller #2 (rev 05)
00:1c.0 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 1 (rev b5)
00:1c.6 PCI bridge: Intel Corporation 6 Series/C200 Series Chipset Family PCI Express Root Port 7 (rev b5)
00:1d.0 USB controller: Intel Corporation 6 Series/C200 Series Chipset Family USB Enhanced Host Controller #1 (rev 05)
00:1e.0 PCI bridge: Intel Corporation 82801 PCI Bridge (rev a5)
00:1f.0 ISA bridge: Intel Corporation C202 Chipset LPC Controller (rev 05)
00:1f.2 SATA controller: Intel Corporation 6 Series/C200 Series Chipset Family 6 port Desktop SATA AHCI Controller (rev 05)
00:1f.3 SMBus: Intel Corporation 6 Series/C200 Series Chipset Family SMBus Controller (rev 05)
02:00.0 Ethernet controller: Intel Corporation 82574L Gigabit Network Connection
03:03.0 VGA compatible controller: Matrox Electronics Systems Ltd. MGA G200eW WPCM450 (rev 0a)


 ./bootutil64e  -IV

Intel(R) Ethernet Flash Firmware Utility
BootUtil version 1.41.03.0
Copyright (C) 2003-2023 Intel Corporation

Image versions in BootIMG.FLB

    Combo Image Version Name 1.3256.0

    Combo Rules                    v4.99.00
    Clp-Loader Option ROM          v3.1.30
    40G Interface Module           v1.0.92
    iSCSI Option ROM               v3.1.80
    iSCSI Setup Option ROM         v3.1.80
    Intel(R) Boot Agent GE         v1.5.89
    Intel(R) Boot Agent XE         v2.4.45
    Intel(R) Boot Agent XE (X550)  v2.4.45
    Intel(R) Boot Agent I40E       v1.1.42
    Intel(R) Boot Agent CL         v0.1.16
    Intel(R) Boot Agent ICE        v2.6.00
    UEFI x64 PCI-E gigabit driver  v9.8.09
    UEFI x64 10 gigabit driver     v8.1.02
    UEFI x64 40 gigabit driver     v4.9.21
    UEFI x64 100 gigabit driver    v4.0.19

11

./bootutil64e  -SI -NIC 1 -FILE 00259075A8CD.image

Intel(R) Ethernet Flash Firmware Utility
BootUtil version 1.41.03.0
Copyright (C) 2003-2023 Intel Corporation

Saving flash firmware image on port 1 to file 00259075A8CD.image...
ERROR: Unsupported feature

Port Network Address Location Series  WOL Flash Firmware                Version
==== =============== ======== ======= === ============================= =======
  1   00259075A8CD     2:00.0 Gigabit YES FLASH Not Present



root@storage-00:~/preboot/APPS/BootUtil/Linux_x64# ./bootutil64e

Intel(R) Ethernet Flash Firmware Utility
BootUtil version 1.41.03.0
Copyright (C) 2003-2023 Intel Corporation

Type BootUtil -? for help

Port Network Address Location Series  WOL Flash Firmware                Version
==== =============== ======== ======= === ============================= =======
  1   00259075A8CC     2:00.0 Gigabit YES FLASH Not Present
  2   00259075A8CD     3:00.0 Gigabit YES FLASH Not Present
dmesg  | grep e100
[    1.121604] e1000e: Intel(R) PRO/1000 Network Driver
[    1.121674] e1000e: Copyright(c) 1999 - 2015 Intel Corporation.
[    1.123751] e1000e 0000:02:00.0: enabling device (0100 -> 0102)
[    1.124496] e1000e 0000:02:00.0: Interrupt Throttling Rate (ints/sec) set to dynamic conservative mode
[    1.203243] e1000e 0000:02:00.0: The NVM Checksum Is Not Valid
[    1.236306] e1000e: probe of 0000:02:00.0 failed with error -5
[    1.236554] e1000e 0000:03:00.0: Interrupt Throttling Rate (ints/sec) set to dynamic conservative mode
[    1.287038] e1000e 0000:03:00.0 0000:03:00.0 (uninitialized): registered PHC clock
[    1.340407] e1000e 0000:03:00.0 eth0: (PCI Express:2.5GT/s:Width x1) 00:25:90:75:a8:cd
[    1.340499] e1000e 0000:03:00.0 eth0: Intel(R) PRO/1000 Network Connection
[    1.340652] e1000e 0000:03:00.0 eth0: MAC: 3, PHY: 8, PBA No: FFFFFF-0FF
[    1.646999] e1000e 0000:03:00.0 eno2: renamed from eth0
[  248.277289] e1000e 0000:03:00.0 eno2: NIC Link is Up 1000 Mbps Full Duplex, Flow Control: None